Différences

Ci-dessous, les différences entre deux révisions de la page.

Lien vers cette vue comparative

Les deux révisions précédentes Révision précédente
Prochaine révision
Révision précédente
gate [2012/03/26 08:55] – admingate [2012/11/08 16:25] (Version actuelle) – [Utilisation Gate version 6.2] cclerget
Ligne 7: Ligne 7:
 One of the most innovative features of GATE is its capability to synchronize all time-dependent components in order to allow a coherent description of the acquisition process. As for the geometry definition, the elements of the geometry can be set into movement via scripting. All movements of the geometrical elements are kept synchronized with the evolution of the source activities. For this purpose, the acquisition is subdivided into a number of time-steps during which the elements of the geometry are considered to be at rest. Decay times are generated within these time-steps so that the number of events decreases exponentially from time-step to time-step, and decreases also inside each time-step according to the decay kinetics of each radioisotope. This allows for the modeling of time-dependent processes such as count rates, random coincidences, or detector dead-time on an event-by-event basis. Moreover, the GEANT4 interaction histories can be used to mimic realistic detector output. In GATE, detector electronic response is modeled as a linear processing chain designed by the user to reproduce e.g. the detector cross-talk, its energy resolution, or its trigger efficiency. One of the most innovative features of GATE is its capability to synchronize all time-dependent components in order to allow a coherent description of the acquisition process. As for the geometry definition, the elements of the geometry can be set into movement via scripting. All movements of the geometrical elements are kept synchronized with the evolution of the source activities. For this purpose, the acquisition is subdivided into a number of time-steps during which the elements of the geometry are considered to be at rest. Decay times are generated within these time-steps so that the number of events decreases exponentially from time-step to time-step, and decreases also inside each time-step according to the decay kinetics of each radioisotope. This allows for the modeling of time-dependent processes such as count rates, random coincidences, or detector dead-time on an event-by-event basis. Moreover, the GEANT4 interaction histories can be used to mimic realistic detector output. In GATE, detector electronic response is modeled as a linear processing chain designed by the user to reproduce e.g. the detector cross-talk, its energy resolution, or its trigger efficiency.
  
-===== Utilisation ===== +====== Utilisation Gate version 6.1 ====== 
-module load gate+<note warning>La parallélisation n'est pas disponible actuellement</note> 
 +Gate est utilisable uniquement en batch mode, pour plus d'informations sur son utilisation : http://wiki.opengatecollaboration.org/index.php/Users_Guide_V6.1 
 +<file bash gate.sge> 
 +#!/bin/bash -l 
 +  
 +#$ -q all.q 
 +#$ -V 
 +#$ -N gate_sge 
 +#$ -cwd 
 +#$ -o $JOB_NAME.$JOB_ID.out 
 +#$ -e $JOB_NAME.$JOB_ID.err 
 + 
 +module load gate/6.1
 source $GATE_HOME/env_gate.sh source $GATE_HOME/env_gate.sh
 +
 +## It is recommended to redirect the terminal output of the
 +## simulation (listing of physics processes, sources, run time, etc.)
 +## by writing it to a text file instead of printing it in the terminal.
 +## This allows one to store the terminal output of each simulation for later viewing
 +
 +Gate -a CoincWindow 10 -a lld 350 -a uld 650 myScanner.mac > terminal_output.txt
 +</file>
 +
 +====== Utilisation Gate version 6.2 ======
 +<note warning>La parallélisation n'est pas disponible actuellement</note>
 +Gate est utilisable uniquement en batch mode, pour plus d'informations sur son utilisation : http://wiki.opengatecollaboration.org/index.php/Users_Guide_V6.2
 +
 +<file bash gate.sge>
 +#!/bin/bash -l
 + 
 +#$ -q all.q
 +#$ -V
 +#$ -N gate_sge
 +#$ -cwd
 +#$ -o $JOB_NAME.$JOB_ID.out
 +#$ -e $JOB_NAME.$JOB_ID.err
 +
 +module load gate/6.2
 +source $ROOT_SCRIPT
 +source $GEANT4_SCRIPT
 +
 +## It is recommended to redirect the terminal output of the
 +## simulation (listing of physics processes, sources, run time, etc.)
 +## by writing it to a text file instead of printing it in the terminal.
 +## This allows one to store the terminal output of each simulation for later viewing
 +
 +Gate -a CoincWindow 10 -a lld 350 -a uld 650 myScanner.mac > terminal_output.txt
 +</file>